Domestic Builder (Unlimited) practice test
Victorian builder registration (DB-U)
- Questions per test
- 40
- Question pool
- 145 source-checked
- Practice timer
- 60 minutes
- Practice pass mark
- 80%
Timer and pass mark are our practice settings, not the official rules. Authority: Building and Plumbing Commission (BPC), Victoria. Review your mistakes bank →
Practice questions for Victorian Domestic Builder (Unlimited) registration: NCC 2025 Housing Provisions, Building Act 1993, Building Regulations 2018, Domestic Building Contracts Act 1995, security of payment and OHS. The Building and Plumbing Commission sets an online, open-book exam and does not publish its question count or pass mark; the 40 questions, 80% and 60 minutes here are practice settings only.
5 Most Common Domestic Builder (Unlimited) Sample Questions & Answers
Preview 5 practice questions with answers and explanations that name their source.
Under the National Construction Code (NCC) Volume Two, how are a detached house and its private garage classified?
Class 1a is a single dwelling such as a detached house. Class 10a is a non-habitable building such as a private garage, carport or shed; Class 10b is for structures such as fences, retaining walls and pools.
Under NCC Part A2, how can the Performance Requirements be satisfied?
NCC A2G1 says Performance Requirements are satisfied by a Performance Solution, a Deemed-to-Satisfy Solution, or a combination. Many people wrongly think Deemed-to-Satisfy is the only lawful route.
Under NCC Housing Provisions 10.2.2, how high must shower area walls be waterproof, measured above the floor substrate?
Clause 10.2.2(1) requires the walls of a shower area to be waterproof not less than 1800 mm above the floor substrate. The older "150 mm above the rose" idea is not in the NCC provision.
For an enclosed shower with a level threshold (no hob), where must the vertical leg of the waterstop finish if a shower screen is installed (NCC Housing Provisions 10.2.17)?
Clause 10.2.17 says the waterstop must finish not less than 5 mm above the finished floor level where a shower screen is installed. Flush is the rule for unenclosed showers (10.2.18).
Under NCC Housing Provisions 10.3.1, what is the minimum ceiling height in a habitable room (excluding a kitchen)?
Clause 10.3.1(1) sets 2.4 m for a habitable room excluding a kitchen. 2.1 m applies to kitchens, corridors, bathrooms and laundries.
Ready to practice all 145 questions?
Take unlimited practice tests with instant feedback or test yourself in the timed exam simulator.
More Trades tests
Sources & Independence
ExamRoo is an independent study aid and is not affiliated with any regulator or training provider. Each question is written from official public sources (legislation, handbooks, regulator guidance and training units) and checked against its source. Relevant authority: Building and Plumbing Commission (BPC), Victoria. Rules change, so always confirm the current requirements with them.
Spotted a mistake, or missing a test?
Every question names its source, and we fix wrong answers within days. Tell us which test and question, or which exam you need next.